9-174
1596
45-1
C
D
RE-CHO-A1
11
FS10
0
8
The 1st-axis (elevation axis)
positions of C3, C4, and C5 of
station axes are not the same.
Setting error
(1)Check the following settings.
·Perform the teaching again so that the 1staxis (elevation axis) positions of C3,
C4, and C5 of station axes are the same.
4498
CANNOT EXECUTE JOB
(NO GRP AXIS)
An attempt was made to execute
an instruction that could not be
executed in a job without control
group.
Setting error
(1)Check the following settings.
·Check the settings for the job instruction with control group.
4499
UNDEFINED POSITION
VARIABLE
Sub Code: The variable number
Setting error
(1)Check the following settings.
·Check the settings for the position type variable.
4500
UNDEFINED USER
FRAME
Sub Code: User coordinate
number
Setting error
(1)Check the following settings.
·Check the settings for the user coordinate.
4501
OUT OF RANGE
(PARALLEL PROCESS)
Sub Code: Task number
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
4502
SL BOARD ON-LINE
ERROR
The option board was detected
not to operate normally at power
ON.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
4507
REFP POS ERROR
(SEARCH MOTION)
Setting error
(1)Check the following settings.
·Perform the teaching again so that the search start point and the motion target
point are not the same.
·Increase the distance between the search start point and the motion target
point.
4508
SPECIFIED ERROR
(COORDINATE)
0
The specified coordinate system
does not exist.
Setting error
(1)Check the following settings.
·Check the settings for the coordinate system which can be used.
1
Designation error of the master
tool coordinate system. This
coordinate system cannot be
used.
Setting error
(1)Check the following settings.
·Check the settings for the coordinate system which can be used.
2
Designation error of the tool
coordinate system. This
coordinate system cannot be
used.
Setting error
(1)Check the following settings.
·Check the settings for the coordinate system which can be used.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
276 of 348