9-146
1596
45-1
C
D
RE-CHO-A1
11
FS10
0
105
An error occurred in instruction
prefetch queue operation in
prereading processing.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
106
An error occurred at IES switching
in prereading processing.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
4402
UNDEFINED COMMAND
(ARITH)
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)Check the following settings.
·the base-axis position must be registered for the system with base-axis
MOVL P00001 BP00001
(3)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
4404
ARITHMETIC ERROR
8
Interpolation such as linear and
circular interpolation cannot be
performed with this manipulator.
Setting error
(1)Check the following settings.
·Change the step (move instruction), where the alarm occurred, to MOVJ.
10
The setting of the form data for
Flip/No Flip is not "B-axis Angle".
Setting error
(1)Check the following settings.
·Set "1" to "S2C658: Type data detail settings".
11
An attempt was made to pass the
B-axis zero degree position
(singular area).
Setting error
(1)Check the following settings.
·Check the teaching position of the job so that the manipulator does not pass
the B-axis zero degree position (singular area).
4406
GROUP AXIS CONTROL
ERROR
1
Designation error for master and
slave
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
2
Slave designation error
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
3
Slave interpolation error
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
248 of 348