9-86
1596
45-1
C
D
RE-CHO-A1
11
FS10
0
4
An error occurred in the
connection detection checking
process of TCP server of the
Ethernet function.
Software operation error
occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
Main CPU board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller.
4134
COOLING FAN SET
ABNORMAL
0
Setting error
(1)Check the following settings.
·Confirm parameter SVS and S2C for the cooling fan.
·Open the front panel to refer to the parameter list on the back.
4137
WRONG EXECUTION
OF SETUALM INST
1
Alarm code specification error
Setting error
(1)Check the following settings.
·Alarm code
Specify the alarm in the range 8000 to 8999.
2
Task specification error
Setting error
(1)Check the following settings.
·Task specification
Specify the task in the range 0 to 4 (7 at expansion).
3
Motion mode specification error
Setting error
(1)Check the following settings.
·Motion mode specification
Set the motion mode to 0 or 1.
4138
WRONG EXECUTION
OF SVON INST
Connection failure
(1)Check the following settings.
·Short-circuit the external servo ON (EXSVON) of MXT terminal block.
Setting error
(1)Check the following settings.
·The concurrent I/O signal #80031 (servo ON condition1) ON
·The concurrent I/O signal #80033 (servo ON condition2) ON
4139
WRONG EXECUTION
OF PRINT INST
Setting error
(1)Check the following settings.
·The setting of the PRINT output conversion spec (character string
specification)
If there is no problem in the setting, delete the corresponding PRINT instruction
and register again.
4140
WRONG EXECUTION
OF DIALOG INST
1
DIALOG instruction control error
Setting error
(1)Check the following settings.
·The tag setting of DIALOG instruction
If no fault is found, delete corresponding DIALOG instruction, and then register
again.
2
Messages and buttons are not
registered.
Setting error
(1)Check the following settings.
·The information of DIALOG instruction message and button
3
Buttons are not registered.
Setting error
(1)Check the following settings.
·The information of DIALOG instruction button
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
188 of 348