9-63
15964
5-1CD
RE-CHO-A1
11
FS
10
0
4
The general servo function was
used for the axis for which the
axis endless function was
enabled.
The general servo function cannot
be used for the axis which the
axis endless function was
enabled.
Setting error
Disable the corresponding axis endless function.
1658
REDUCTION STOP
SPECIFIC. ERROR
(SV)
1
The servo float function was used
for the axis for which the
deceleration stop function was
enabled.
The servo float function cannot be
used for the axis which the
deceleration stop function was
enabled.
Setting error
Check the JOB.
2
The specified axis speed control
function was executed for the axis
which the deceleration stop
function was enabled.
Specified axis speed control
function cannot be used for the
axis which the deceleration stop
function was enabled.
Setting error
Check the JOB.
1664
MICRO PRG EXECUTE
TIME OVER(SV)
Sub code: specifies the axis that
alarm occurred.
Servo control board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
1665
MICRO PROGRAM
SYNC. ERROR (SV)
Sub code: specifies the axis that
alarm occurred.
Servo control board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
1666
FILE RECEIVE
INCOMPLETE (SERVO)
Sub code: specifies the axis that
alarm occurred.
Servo control board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
1667
RESOLUTION
CONVERSE CONST
ERROR
(SV)
Servo control board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
165 of 348