9-173
15964
5-1CD
RE-CHO-A1
11
FS
10
0
136
Pulse linked JOG function
specification error
Setting error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
137
Dual drive control specification
error
Setting error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
138
Notch filter supported
acceleration and deceleration
tuning: Notch filter function setting
error
Setting error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
139
Notch filter supported
acceleration and deceleration
tuning: Notch filter (z2) setting
error
Setting error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
4497
DEFECTIVE TAUGHT
POINT (CALIB)
1
Some of the teaching points for
master-group are on the same
point.
Setting error
(1)Check the following settings.
·Perform the teaching again so that the teaching points are different from one
another.
2
Some of the teaching points for
slave-group are on the same
point.
Setting error
(1)Check the following settings.
·Perform the teaching again so that the teaching points are different from one
another.
3
The 2nd-axis positions of C3, C4,
and C5 of station axes are not the
same.
Setting error
(1)Check the following settings.
·Perform the teaching again so that the 2ndaxis positions of C3, C4, and C5 of
the station axes are the same.
4
The 1st-axis positions of C1, C2,
and C3 of station axes are not the
same.
Setting error
(1)Check the following settings.
·Perform the teaching again so that the 1staxis positions of C1, C2, and C3 of
station axes are the same.
5
The 2nd-axis positions of C1, C2,
and C3 of station axes are the
same.
Setting error
(1)Check the following settings.
·Perform the teaching again so that the teaching positions are different from
one another.
6
The 1st-axis rotation direction of
C3, C4, and C5 of station axes
are not the same.
Setting error
(1)Check the following settings.
·Perform the teaching again so that the 1staxis rotation direction of C3, C4, and
C5 of station axes are the same.
7
The 1st-axis (elevation axis)
positions of C1, C2, and C3 of
station axes are not the same.
Setting error
(1)Check the following settings.
·Perform the teaching again so that the 1staxis (elevation axis) positions of C1,
C2, and C3 of station axes are the same.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
275 of 348