3
Maintenance and Inspections
3.1 Daily Inspections
3-2
159645-1CD
RE-CHO-A111
FS100
Carry out the following inspections.
Inspection
Equipment
Inspection Item
Method
Inspection
Interval
Comments
FS100 Controller
exterior
Check for damages
and cracks
Check visually
As required
Check for damages
and loose
connectors
Power supply cable
Check for damages or
connections.
Check visually
As required
Check for damages
and loose
connectors
Manipulator cable
(between the FS100
and the manipulator)
Check for damages or
connections.
Check visually
As required
Check for damages
and loose
connectors
Cover mounting
screws
Check for defect or
loose of the screws
Use screw driver
As required
Tighten loose
screws
Cooling fan
Check the operation
Check visually
As required
When the power is
turned ON
Emergency stop
button
1)
(programming
pendant)
Check the operation
By activating the
button
Before the
manipulator
operation
When the SERVO
is turned ON
Enable switch
(programming
pendant)
Check the operation
By activating the
switch
Before the
manipulator
operation
During the teach
mode
Battery
(for the system)
Message indication
Check LED lights
Check visually
As required
Before blocking the
power supply
1 Be sure to confirm that the SERVO can be turned OFF by pressing the external emergency button when the
programming pendant is not used.
The external emergency button is prepared by the user.
30 of 348