9-78
1596
45-1
C
D
RE-CHO-A1
11
FS10
0
10
Use memory is lacking and the
area could not be obtained.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
11
The setting value of measurement
item (FT) is incorrect.
Correct the setting value of a measurement item.
12
The data for the vision execution
command is incorrect.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
48
The number of waiting commands
sent by Vision sensor exceeded
the limit.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)Check the command sent by Vision sensor
(3)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
4126
CANNOT EXECUTE
AUTO PMT
1
System error
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
2
PBOX cannot be edited.
Setting error
(1)Check the following settings.
·I/O status of the edit prohibit signal
The edit prohibit signal cannot input.
3
The source job cannot be edited.
Setting error
(1)Check the following settings.
·The prohibit status of source job
If the source job is protected from editing, it cannot be edited.
4
The converted job cannot be
edited.
Setting error
(1)Check the following settings.
·The prohibit status of converted job
If the converted job is protected from editing, it cannot be edited.
5
The memory area for job area is
insufficient.
Software operation error
occurred
(1)Reset the alarm.
(2)If the error occurs again, delete unused jobs.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job file.
In that case, delete the unused job.
(4)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
180 of 348