9-43
15964
5-1CD
RE-CHO-A1
11
FS
10
0
12
Unable to prepare the current
position
Main CPU board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
Software operation error
occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
1053
SYSTEM ERROR
(EVENT)
Sub Code
1 to 8: Signifies the internal
software error at event process.
Software operation error
occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
1100
SYSTEM ERROR
Sub Code
C, B, F : Sub code of unknown
alarm
Software operation error
occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
RAM software data error
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
1101
SYSTEM ERROR
(MAN-MACHINE
MECHA)
Sub Code
0 to 6: Internal control error in
software
Software operation error
occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
1102
SYSTEM ERROR
(MAN-MACHINE APPLI)
Sub Code
0 to 526: Internal control error in
software
Software operation error
occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
1103
SYSTEM ERROR
(EVENT)
Software operation error
occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
1104
SYSTEM ERROR
(CIO)
Sub Code
1000_0000: I/O module setting
error
Connection failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connecting or inserting state of the
following cables or connectors.
·IO module cable of the corresponding slot.
·24V power of the corresponding IO module.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
145 of 348