9-182
1596
45-1
C
D
RE-CHO-A1
11
FS10
0
2
The extraction start position
exceeds the character string
length at MID$ instruction
execution.
Setting error
(1)Check the following settings.
·Check the settings for the data of the character string to be extracted.
4546
CANNOT EXCUTE
SYSTEM JOB
Sub Code: System number
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
4547
PRIMITIVE ERROR
Sub Code: Error code
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
4548
CANNOT OPERATE
SPECIFIED EVENT
Sub Code: System number
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
4549
NOT EXECUTION OF
INIEVNT
Sub Code: System number
Setting error
(1)Check the following settings.
·Execute an INIEVNT instruction before executing an event related instruction.
4550
CANNOT EXECUTE
INST (USER JOB)
Sub Code: System number
Setting error
(1)Check the following settings.
·This instruction cannot be executed in the system job. Correct the job so that
the instruction is executed in the user job.
4565
SOFTWARE UNMATCH
1
The multi-layer welding function is
not used.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
3
The TURBO function is not used.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
5
The conveyor/press
synchronization function is not
used.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
6
The shared motion function is not
used.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
284 of 348