9-161
15964
5-1CD
RE-CHO-A1
11
FS
10
0
4464
OVER BCD RANGE
Setting error
(1)Check the following settings.
·Correct the BCD data so that it is within the limit.
4465
OVER BINARY RANGE
(PARITY CHECK)
Setting error
(1)Check the following settings.
·Correct the binary data so that it is within the limit.
4466
OFFLINE UNDEFINED
COMMAND (ARITH)
0
An undefined command was
issued to the offline position-data
preparation section.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
4467
USER COORD STEP
NOT ENOUGH
Setting error
(1)Check the following settings.
·Correct the JOB that the number of steps will be three or more.
4468
ROBOT CALIBRATION
DATA ERROR
1
The calibration between
manipulators cannot be executed
for this model.
Setting error
(1)Check the following settings.
·Do not use a coordinated motion with this manipulator.
2
The master group and the slave
group are set to the same group.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
3
Incorrect designation of the
control group for master group
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
4
Incorrect designation of the
control group for slave group
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
5
Incorrect designation of the
occupation control group for
calibration data
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
6
Incorrect designation of the
enabling control group for
calibration data
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
7
Among three points in the master-
group's calibration data, two or
three points are on the same
point.
Setting error
(1)Check the following settings.
·Teach the data for calibration so that each point is different.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
263 of 348