9-204
1596
45-1
C
D
RE-CHO-A1
11
FS10
0
3090
In a file sever task, file close
error.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your YASKAWA representative about
occurrence status (operating procedure).
4718
I/O MODULE 24V
POWER ERROR
Sub Code: I/O Board slot(BIT)
For example slot3 case:
(0000_0100), slot4
case:(0000_1000). If multiple
I/O boards detecting the error,
multiple bits are set. (Standard
shipping of FS100, An I/O
board is in slot3.)
Fuse failure
I/O board (LIO08R/09R) detected 24V power failure. Check the
following items.
(1) Check the fuse on the front panel of FS100, and replace it if it was
cut.
(2) Check the CN3 connecter and the cable of the I/O board.
(3) If the error occurs again, replace the LIO08R/09R board.
4719
BINARY ETHERNET
CLIENT FUNC ERR
1
Detect message library
initialize error.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your YASKAWA representative about
occurrence status (operating procedure).
2
Failed in the generation of the
file function task.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your YASKAWA representative about
occurrence status (operating procedure).
3
Failed in the generation of the
RC function task.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your YASKAWA representative about
occurrence status (operating procedure).
4
Detect I/F data error.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your YASKAWA representative about
occurrence status (operating procedure).
10
Detect undefined error.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your YASKAWA representative about
occurrence status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
306 of 348