YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
501
Setting Value
Function
Description
Ref.
13
Reverse Jog
Sets the command to operate the motor in the reverse direction at the Jog Frequency set in
d1-17 [Jog Reference]
.
14
Fault Reset
Sets the command to reset the current fault when the Run command is inactive.
Note:
The drive ignores the fault reset command when the Run command is active. Remove the Run command
before trying to reset a fault.
15
Fast Stop (N.O.)
Sets the command to ramp to stop in the deceleration time set in
C1-09 [Fast Stop Time]
when the input terminal is
ON while the drive is operating.
16
Motor 2 Selection
Switches between motor 1 or motor 2. Switch the motor while the motor is stopped.
ON : Selects motor 2
OFF : Selects motor 1
17
Fast Stop (N.C.)
Sets the command to ramp to stop in the deceleration time set in
C1-09 [Fast Stop Time]
when the input terminal is
ON while the drive is operating.
1A
Accel/Decel Time
Selection 2
Set this function and
H1-xx = 7 [Accel/Decel Time Selection 1]
together. Sets the drive to use
Acceleration/
Deceleration Time 3 [C1-05, C1-06]
or
Acceleration/Deceleration Time 4 [C1-07, C1-08]
.
1B
Programming Lockout
Sets the command to prevent parameter changes when the terminal is OFF.
ON : Programming Lockout
OFF : Parameter Write Prohibit
1E
Reference Sample Hold
Samples the analog frequency reference input to the terminals A1, A2, or A3, and continues operation at the
sampled frequency.
20 to 2F
External Fault
Sets a command to stop the drive when a failure or fault occurs on an external device.
20 : External Fault (NO-Always-Ramp)
21 : External Fault (NC-Always-Ramp)
22 : External Fault (NO-@Run-Ramp)
23 : External Fault (NC-@Run-Ramp)
24 : External Fault (NO-Always-Coast)
25 : External Fault (NC-Always-Coast)
26 : External Fault (NO-@Run-Coast)
27 : External Fault (NC-@Run-Coast)
28 : External Fault (NO-Always-FStop)
29 : External Fault (NC-Always-FStop)
2A : External Fault (NO-@Run-FStop)
2B : External Fault (NC-@Run-FStop)
2C : External Fault (NO-Always-Alarm)
2D : External Fault (NC-Always-Alarm)
2E : External Fault (NO-@Run-Alarm)
2F : External Fault (NC-@Run-Alarm)
30
Light-load Accel 1
Enabled
Enables or disables the selection of Light-Load Accel 1 Enabled function.
ON : Enabled
OFF : Disable
31
Forward Travel Limit
(N.O.)
If you turn on a terminal while a motor rotates forward, the drive turns off the brake release command (holds the
brake), the motor coasts to stop, and the output frequency becomes 0. If you turn on a terminal while a motor
rotates in reverse, the motor will not stop.
ON : Disables the forward operation Run command.
OFF : Enables the forward operation Run command.
32
Forward Travel Limit
(N.C.)
If you turn off a terminal while a motor rotates forward, the drive turns off the brake release command (holds the
brake), the motor coasts to stop, and the output frequency becomes 0. If you turn off a terminal while a motor
rotates in reverse, the motor will not stop.
ON : Enables the forward operation Run command.
OFF : Disables the forward operation Run command.
33
Reverse Travel Limit (N.
O.)
If you turn on a terminal while a motor rotates in reverse, the drive turns off the brake release command (holds the
brake), the motor coasts to stop, and the output frequency becomes 0. If you turn on a terminal while a motor
rotates forward, the motor will not stop.
ON : Disables the reverse operation Run command.
OFF : Enables the reverse operation Run command.
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Summary of Contents for CR700
Page 1: ......
Page 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Page 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...