10.15 T: Motor Tuning
◆
T0: Tuning Mode Selection
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
T0-00
(1197)
Tuning Mode Selection
Selects the type of Auto-Tuning to be used.
0 : Motor Parameter Tuning
1 : Control Tuning
0
(0, 1)
◆
T1: Induction Motor Auto-Tuning
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
T1-00
(0700)
Motor Selection
Sets which motor to tune when motor switching is enabled. You must use the keypad to
set this parameter. You cannot use external input terminals to set it.
Note:
You can set this parameter when you select motor switching If you disable motor
switching, this parameter will not appear.
1 : Motor 1 (sets E1-xx, E2-xx)
2 : Motor 2 (sets E3-xx, E4-xx)
3 : Motor 3 (sets E7-xx)
1
(1 - 3)
T1-01
(0701)
Auto-Tuning Mode
Selection
Sets the type of Auto-Tuning.
0 : Rotational Auto-Tuning
1 : Stationary Auto-Tuning 1
2 : Stationary Line-Line Resistance
Determined by A1-02
(Determined by A1-02)
T1-02
(0702)
Motor Rated Power
Sets the rated output power (kW) of the motor.
Determined by o2-04
(0.00 - 590.0 kW)
T1-03
(0703)
Motor Rated Voltage
Sets the rated voltage (V) of the motor. Enter the base speed voltage for constant output
motors.
Determined by o2-04
(200 V Class: 0.0 - 255.5
V, 400 V Class: 0.0 -
511.0 V)
T1-04
(0704)
Motor Rated Current
Sets the rated current (A) of the motor.
Determined by o2-04
(10% to 200% of the
drive rated current)
T1-05
(0705)
Motor Base Frequency
Sets the base frequency (Hz) of the motor.
50.0 Hz
(0.0 - 590.0 Hz)
T1-06
(0706)
Number of Motor Poles
Sets the number of motor poles.
4
(2 - 120)
T1-07
(0707)
Motor Base Speed
Sets the motor base speed for Auto-Tuning (min
-1
(r/min)).
1750 min
-1
(r/min)
(0 - 35400 min
-1
(r/min))
T1-08
(0708)
Encoder Pulse Count
(PPR)
Sets the number of PG (pulse generator, encoder) pulses.
600 ppr
(0 - 60,000 ppr)
T1-09
(0709)
Motor No-Load Current
Sets the no-load current of the motor.
-
(0A - T1-04; max. of
2999.9)
T1-10
(070A)
Motor Rated Slip
Frequency
Sets motor rated slip.
-
(0.000 - 20.000 Hz)
T1-12
(0BDB)
Test Mode Selection
Sets the function to enable Test Mode after Stationary Auto-Tuning. When you can
operate the motor with a light load attached after Stationary Auto-Tuning is complete,
enable this parameter.
Note:
You must first set
T1-10 = 0 [Motor Rated Slip Frequency = 0 Hz]
to enable this
parameter.
0 : No
1 : Yes
0
(0, 1)
T1-13
(0BDC)
No-Load Voltage
Sets the no-load voltage of the motor. When the no-load voltage at rated speed is
available, for example on the motor test report, set the voltage in this parameter. If the
no-load voltage is not available, do not change this parameter.
Note:
To get the same qualities as a Yaskawa 1000-series drive or previous series drive,
set this parameter =
T1-03 [Motor Rated Voltage]
.
90% of T1-03
(200 V Class: 0.0 - 255.0
V, 400 V Class: 0.0 -
510.0 V)
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Summary of Contents for CR700
Page 1: ......
Page 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...