5.3 MEMOBUS/Modbus Communications
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
319
Register No.
(Hex.)
Description
002D
U1-11 [Output Terminal Status]
bit 0
MFDO (terminal M1-M2)
1: ON, 0: OFF
bit 1
MFDO (terminal M3-M4)
1: ON, 0: OFF
bit 2
MFDO (terminal M5-M6)
1: ON, 0: OFF
bit 3 - 6
Reserved
bit 7
Fault relay output (terminal MA-MC / MB-MC)
1: ON, 0: OFF
bit 8 - F
Reserved
002E - 0030
Reserved
0031
U1-07 [DC Bus Voltage] (unit: 1 V)
0032
U1-09 [Torque Reference] (unit: 1%)
0033
Reserved
0034
0035
Product code 2 [ASCII], region
0036 - 003C
Reserved
003D
Communications error description
Note:
The description of the communications error is saved until the fault is reset.
bit 0
CRC Error
bit 1
Data Length Error
bit 2
Reserved
bit 3
Parity Error
bit 4
Overrun Error
bit 5
Framing Error
bit 6
Timeout
bit 7 - F
Reserved
003E
Output frequency
Units: min
-1
or r/min
Note:
Set
E2-04, E4-04 [Motor Poles]
.
003F
0.01% units
0040 - 004A
Used with
U1-xx [Operation Status Monitors]
. Refer to the
U Monitors
for parameter details.
Summary of Contents for CR700
Page 1: ......
Page 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Page 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...