SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Drive Model
Maximum Applicable Motor Output
kW (HP)
Input Current Rating
A
Semiconductor Protection Fuse
Rated Current
Manufacturer: EATON/Bussmann
4060
30 (40)
58.3
FWH-250A
4075
37 (50)
71.5
FWH-275A
4091
45 (60)
86.5
FWH-275A
4112
55 (75)
105
FWH-300A
4150
75 (100)
142
FWH-325A
FWH-400A
4180
90 (125)
170
FWH-500A
4216
110 (150)
207
FWH-600A
4260
132 (175)
248
FWH-700A
4304
160 (200)
300
FWH-800A
4371
200 (250)
373
FWH-1000A
4414
220 (300)
410
FWH-1200A
4453
250 (335)
465
FWH-1200A
4605
315 (400)
584
FWH-1400A
FWH-1600A
*1
Yaskawa recommends a fuse with a large rated current for applications with repeated loads.
◆
Low Voltage Wiring for Control Circuit Terminals
Low voltage wiring must be provided in accordance with the NEC (National Electric Code), the CEC (Canadian
Electric Code, Part I), and any additional local codes. The NEC class 1 circuit conductor is recommended. Use the
UL approved class 2 power supply for external power supply.
Table 4.20 Power Supply Used for Control Circuit Terminals
Input/Output
Terminal Sign
Power Supply Specifications
Digital inputs
S1 to S10, SN, SC, SP
The LVLC power supply in the drive is used.
Use the UL approved class 2 power supply for external
power supply.
Analog input
A1 to A3, AC, +V, -V
The LVLC power supply in the drive is used.
Use the UL approved class 2 power supply for external
power supply.
Analog output
FM, AM, AC
The LVLC power supply in the drive is used.
Safe disable Input
H1, H2, HC
The LVLC power supply in the drive is used.
Use the UL approved class 2 power supply for external
power supply.
Open-collector output
P1, C1, P2, C2
Use the UL approved class 2 power supply.
Serial communication input/output
D+, D-, AC
The LVLC power supply in the drive is used.
Use the UL approved class 2 power supply for external
power supply.
24 V external power supply
PS, AC
Use the UL approved class 2 power supply.
◆
Drive Motor Overload and Overheat Protection
The drive motor overload and overheat protection function complies with the NEC (National Electric Code) and
the CEC (Canadian Electric Code, Part I).
Set the
Motor Rated Current
and
L1-01 to L1-04 [Motor Overload Protection Select]
properly to enable motor
overload and overheat protection.
Set the motor rated current with
E2-01 [Motor Rated Current (FLA)]
.
■
E2-01: Motor Rated Current (FLA)
No.
(Hex.)
Name
Description
Default
(Range)
E2-01
(030E)
Motor Rated Current (FLA)
Sets the motor rated current in amps.
Determined by o2-04
(10% to 200% of the drive
rated current)
V/f
CL-V/f
OLV
CLV
AOLV
Summary of Contents for CR700
Page 1: ......
Page 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Page 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...