11.11 o: Keypad-Related Settings
782
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
A - Set
Ux-xx [Monitors]
(Monitor 1) to
o1-24
.
B - Set
Ux-xx [Monitors]
(Monitor 2) to
o1-25
.
C - Set the maximum value of Monitor 2 to
o1-50
.
D - Set the minimum value of Monitor 2 to
o1-49
.
E - Set the time scale to
o1-51
.
F - Set the minimum value of Monitor 1 to
o1-47
.
G - Set the maximum value of Monitor 1 to
o1-48
.
Figure 11.101 Trend Plot Display
■
o1-01: User Monitor Selection
No.
(Hex.)
Name
Description
Default
(Range)
o1-01
(0500)
RUN
User Monitor Selection
Sets the
U monitor
for the Drive Mode. This parameter is only available with an LED keypad.
106
(104 - 999)
When the drive is in Drive Mode, each time pushing
on the keypad will show the following data: frequency
reference → rotational direction → output frequency → output current →
o1-01
selection.
Set the
x-xx
portion of the monitoring parameter
Ux-xx
that appears in the fifth position in Drive Mode. For
example, to display
U1-05 [Motor Speed]
, set
o1-01 = 105
.
Note:
•
You cannot select
U2 monitor [Fault Trace]
and
U3 Monitor [Fault History]
.
•
The selectable monitors vary depending on the control method.
■
o1-02: Monitor Selection at Power-up
No.
(Hex.)
Name
Description
Default
(Range)
o1-02
(0501)
RUN
Monitor Selection at Power-
up
Sets the monitor item that the keypad screen shows after you energize the drive. Refer to
“
U:
Monitors
”
for information about the monitor items that the keypad screen can show. This
parameter is only available with an LED keypad.
1
(1 - 5)
1 : Frequency Reference (U1-01)
2 : Direction
3 : Output Frequency (U1-02)
4 : Output Current (U1-03)
5 : User Monitor (o1-01)
Shows the monitor item selected in
o1-01 [User Monitor Selection]
.
■
o1-03: Frequency Display Unit Selection
No.
(Hex.)
Name
Description
Default
(Range)
o1-03
(0502)
Frequency Display Unit
Selection
Sets the display units for the frequency reference and output frequency.
Determined by A1-02
(0 - 4)
Note:
When the setting value of
o1-03
is changed, the these monitor and parameter units change.
•
U1-01 [Frequency Reference]
•
U1-02 [Output Frequency]
•
U1-05 [Motor Speed]
•
U1-16 [SFS Output Frequency]
•
d1-01 to d1-17 [Reference 1 to 8 and Jog Reference]
0 : 0.01Hz
G
F
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Summary of Contents for CR700
Page 1: ......
Page 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Page 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...