YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
503
Setting Value
Function
Description
Ref.
67
Communications Test
Mode
Set the function for the drive to self-test RS-485 serial communications operation.
72
Zero Servo
Sets the function to hold a stopped motor.
100 - 1FF
Inverse Inputs of 0 to FF Sets the function of the selected MFDI to operate inversely. To select the function, enter
“
1xx
”
, where
“
xx
”
is the
function setting value.
Note:
You cannot use inverse input for all functions. Refer to
for more information.
◆
H2: Digital Outputs
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
H2-01
(040B)
Term M1-M2 Function
Selection
Sets the function for MFDO terminal M1-M2.
Note:
When you do not use the terminal or when you use the terminal in through mode,
set this parameter to
F
.
21
(0 - 1FF)
H2-02
(040C)
Term M3-M4 Function
Selection
Sets the function for MFDO terminal M3-M4.
Note:
When you do not use the terminal or when you use the terminal in through mode,
set this parameter to
F
.
0
(0 - 1FF)
H2-03
(040D)
Term M5-M6 Function
Selection
Sets the function for MFDO terminal M5-M6.
Note:
When you do not use the terminal or when you use the terminal in through mode,
set this parameter to F.
2
(0 - 1FF)
H2-04
(040E)
Term P1-C1 Function
Selection
Sets the function for MFDO terminal P1-C1.
Note:
When you do not use the terminal or when you use the terminal in through mode,
set this parameter to F.
6
(0 - 1FF)
H2-05
(040F)
Term P2-C2 Function
Selection
Sets the function for MFDO terminal P2-C2.
Note:
When you do not use the terminal or when you use the terminal in through mode,
set this parameter to F.
10
(0 - 1FF)
H2-06
(0437)
Watt Hour Output Unit
Selection
Sets the unit for the output signal when
H2-01 to H2-05 = 39 [MFDO Function
Selection = Watt Hour Pulse Output]
.
0 : 0.1 kWh units
1 : 1 kWh units
2 : 10 kWh units
3 : 100 kWh units
4 : 1000 kWh units
0
(0 - 4)
H2-07
(0B3A)
Modbus Register 1
Address Select
Sets the address of the MEMOBUS/Modbus register output to the MFDO terminal.
0001
(0001 - 1FFF)
H2-08
(0B3B)
Modbus Register 1 Bit
Select
Sets the bit of the MEMOBUS/Modbus register output to the MFDO terminal.
0000
(0000 - FFFF)
H2-09
(0B3C)
Modbus Register 2
Address Select
Sets the address of the MEMOBUS/Modbus register output to the MFDO terminal.
0001
(0001 - 1FFF)
H2-10
(0B3D)
Modbus Register 2 Bit
Select
Sets the bit of the MEMOBUS/Modbus register output to the MFDO terminal.
0000
(0000 - FFFF)
H2-20
(1540)
Comparator 1 Monitor
Selection
Sets the monitor number for comparator 1. Set the
x-xx
part of the
Ux-xx [Monitor]
. For
example, set
H2-20 = 102
to monitor
U1-02 [Output Frequency]
.
102
(000 - 999)
H2-21
(1541)
Comparator 1 Lower
Limit
Sets the lower limit detection level for comparator 1 when the full scale analog output
for the monitor selected in
H2-20 [Comparator 1 Monitor Selection]
is the 100% value.
0.0%
(0.0 - 300.0%)
H2-22
(1542)
Comparator 1 Upper
Limit
Sets the upper limit detection level for comparator 1 when the full scale analog output
for the monitor selected in
H2-20 [Comparator 1 Monitor Selection]
is the 100% value.
0.0%
(0.0 - 300.0%)
H2-23
(1543)
Comparator 1 Hysteresis
Sets the hysteresis level for comparator 1 as a percentage of the full scale analog output
for the monitor selected in
H2-20 [Comparator 1 Monitor Selection]
.
0.0%
(0.0 - 10.0%)
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Summary of Contents for CR700
Page 1: ......
Page 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Page 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...