668
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Parameter
CC-Link
SI-C3
MECHATROLINK-II
SI-T3
MECHATROLINK-III
SI-ET3
PROFIBUS-DP
SI-P3
CANopen
SI-S3
F7-17 - F7-42
-
-
-
-
-
F7-60 - F7-79
-
-
-
x
-
Table 11.23 Correspondence Between Communication Protocols and Parameters (SI-N3, SI-EM3, SI-EP3, and SI-EN3)
Parameter
DeviceNet
SI-N3
Modbus TCP/IP
SI-EM3
PROFINET
SI-EP3
EtherNet/IP
SI-EN3
F6-01 - F6-03
x
x
x
x
F6-04
-
-
-
-
F6-06 - F6-08
x
x
x
x
F6-10, F6-11
-
-
-
-
F6-14
x
x
x
x
F6-16
x
x
x
x
F6-20, F6-21
-
-
-
-
F6-22
-
-
-
-
F6-23 - F6-26
-
-
-
-
F6-30 - F6-32
-
-
-
-
F6-35, F6-36
-
-
-
-
F6-50 - F6-71
x
-
-
-
F7-01 - F7-15
-
x
x
x
F7-16
-
x
-
-
F7-17 - F7-42
-
-
x
x
F7-60 - F7-79
-
-
-
-
■
F6-01: Communication Error Selection
No.
(Hex.)
Name
Description
Default
(Range)
F6-01
(03A2)
Communication Error
Selection
Selects the operation of the drive when the drive detects
bUS [Option Communication Error]
.
1
(0 - 5)
0 : Ramp to Stop
The drive ramps the motor to stop according to the deceleration time. Fault relay output terminal MA-MC will
turn ON, and MB-MC will turn OFF.
1 : Coast to Stop
The drive output shuts off and the motor coasts to stop. Fault relay output terminal MA-MC will turn ON, and
MB-MC will turn OFF.
2 : Fast Stop (Use C1-09)
The drive stops the motor using the deceleration time set in
C1-09 [Fast Stop Time]
. Fault relay output terminal
MA-MC will turn ON, and MB-MC will turn OFF.
3 : Alarm Only
The keypad shows
bUS
, and the drive continues operation with the current frequency reference.
Note:
Prepare safety protection equipment and systems such as fast stop switches separately.
The output terminal set for
Alarm [H2-01 to H2-05 = 10]
switches ON.
4 : Alarm (Run at
d1-04
)
The keypad shows
bUS
, and the drive continues operation at the speed set in
d1-04 [Reference 4].
Note:
Prepare safety protection equipment and systems such as fast stop switches separately.
5 : Alarm - Ramp Stop
The motor is stopped during the deceleration time set in
C1-02 [Deceleration Time 1]
when
bUS
is detected.
When the
bUS
fault clears, the motor starts accelerating to return to the previous frequency reference.
V/f
CL-V/f
OLV
CLV
AOLV
Summary of Contents for CR700
Page 1: ......
Page 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Page 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...