YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
657
■
F2-01: Analog Input Function Selection
No.
(Hex.)
Name
Description
Default
(Range)
F2-01
(038F)
Analog Input Function
Selection
Sets the input method for the analog reference used with AI-A3.
0
(0, 1)
Note:
When the AI-A3 card is not mounted in the drive, analog input terminals A1 to A3 on the drive are always enabled. The setting of this
parameter does not have an effect.
0 : 3 Independent Channels
Set
F2-01 = 0
to increase the precision of A/D conversion when you use the functions for terminals A1 to A3 on
the drive as they are. You can input the MFAI signal from terminals V1 through V3 for AI-A3. The functions for
terminals A1, A2, and A3 on the drive are sent to terminals V1, V2, and V3 for AI-A3. Use gain and bias
adjustment when you input current to set signals to have negative numbers.
Note:
•
Set
b1-01 = 1 [Frequency Reference Selection 1 = Analog Input]
to set inputs individually.
•
If
F2-01 = 0
and
b1-01 = 3 [Option PCB]
, the drive will detect
oPE05 [Run Cmd/Freq Ref Source Sel Err]
.
shows the individual input of analog inputs.
H3-xx parameters
set the function to input the analog
reference received from the AI-A3 card and to adjust the gain and bias of these signals.
Figure 11.49 Analog Input Reference Individual Input Block Diagram
1 : 3 Channels Added Together
Set
b1-01 = 3 [Option PCB]
to set addition input.
You can input the frequency reference directly. The sum value when you add the input from terminals V1 to V3
becomes the frequency reference.
Set
F2-01 = 1
to use the AI-A3 card as addition input.
shows addition input. Use
F2-02 [Analog Input Option Card Gain]
and
F2-03 [Analog Input Option
Card Bias]
to adjust the analog reference gain and bias for addition input.
Figure 11.50 Analog Input Reference Addition Input Block Diagram
Use F2-02 and F2-03 to Adjust the Input Status
When the bias set in
F2-03
is 0%, the gain in
F2-02
and the addition input value set the ratio (%) of the maximum
output frequency output as the frequency reference.
V/f
CL-V/f
OLV
CLV
AOLV
Summary of Contents for CR700
Page 1: ......
Page 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Page 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...