2 - 6
Electrical Wiring (1)
Continued
Terminal
arrangement
Figure 2-4 Terminal arrangement for remote converter
1-contact input and 1-contact output
2-contact input
E
STATUS IN STATUS OUT
SB
SA
C
A
+
–
+
–
POWER
P.OUT
I.OUT
L
N
X
Y
+
–
+
–
B
E
STATUS IN1 STATUS IN2
SB
SA
C
A
+
–
+
–
POWER
P.OUT
I.OUT
L
N
X
Y
+
–
+
–
B
2-contact output
Terminal arrangement for integral converter
On an integral converter, terminal symbols X, Y, SB, SA, A, B, C, and E
are not indicated as on the remote converter, because these terminals are
not used.
Terminal arrangement of a 24 V DC converter
The 24 V DC converter has a terminal marked "POWER DC24V" instead
of "POWER", as on the remote converter. Pay close attention to the "+"
and "–" polarity.
(Continued on next page)
E
STATUSOUT2 STATUS OUT1
SB
SA
C
A
+
–
+
–
POWER
P.OUT
I.OUT
L
N
X
Y
+
–
+
–
B
Summary of Contents for MagneW3000 PLUS
Page 1: ...CM2 MGG210 2001 MagneW3000 PLUS Smart Electromagnetic Flowmeter Model MGG14C User s Manual ...
Page 13: ...xi MEMO ...
Page 25: ...1 12 ...
Page 41: ...2 16 MEMO ...
Page 53: ...3 12 MEMO ...
Page 114: ...4 61 MEMO ...