4 - 50
Setting the Pulse Width
Introduction
The pulse width that will be output from the pulse output terminal can be set
when a pulse output board has been selected. This is used to set the pulse
width so that the duty ratio at the upper right of the 16-digit display will not
exceed 70%.
When changing the pulse width with a double range, use the wider range.
Default setting
NUM
010.00
Setting range
Pulse width: "NUM", "DUTY"
Pulse width: 000.00 - 999.99 ms
When "NUM" is selected, the pulse width can be set freely.
When "DUTY" is selected, "DUTY" is fixed at 50%.
Open the pulse width setup
screen by following the steps to
enter the Engineering Mode.
Use the key to move the
cursor to "NUM".
By touching the key, the
screen used to enter a numeri-
cal value pulse width will
change to the screen used to fix
the duty ratio at 50%.
To enter the pulse width using a
numerical value, return to the
numerical value entry screen
by using the key, and move
the cursor to the desired digits
using the key.
1
Screen
Procedure
Step
2
3
4
Use the and keys to
change the numbers.
Touch the key to move the
cursor to the "#".
5
6
# PLS 27.778 %
WID NUM 010.00ms
# PLS 27.778 %
WID NUM 010.00ms
# PLS
WID DUTY 50%
# PLS 27.778 %
WID NUM 010.00ms
# PLS 13.889 %
WID NUM 005.00ms
# PLS 13.889 %
WID NUM 005.00ms