Select either the Engineering Mode (to operate the setting parameters of the
electromagnetic flowmeter) or the Maintenance Mode (to perform adjust-
ments or inspection).
Note:
• In some cases, a mode selection screen will not open, depending
on the write-protect setting. Only the Engineering Mode selection
screen will open if the write-protect switches on the main board are
used to select level 1, 2, or 3.
If level 0 is selected, both the Engineering Mode and the
Maintenance Mode will open. Refer to Chapters 3 and 5.
To enter the Engineering Mode
Call up the Engineering Mode
selection screen by following
the steps to enter the Operator’s
Mode.
Touch the key once.
Touch the key, and the dis-
play will change to the Engi-
neering Mode.
Two seconds later, the display
shown at right will appear.
Screen
Procedure
Step
1
3
(Continued on next page)
4
2
*
MODE ENTER
ENGINEERING
*
MODE ENTER
ENGINEERING
#
ENGINEERING
MODE
#
ID SET
XXXXXXXX
Summary of Contents for MagneW3000 PLUS
Page 1: ...CM2 MGG210 2001 MagneW3000 PLUS Smart Electromagnetic Flowmeter Model MGG14C User s Manual ...
Page 13: ...xi MEMO ...
Page 25: ...1 12 ...
Page 41: ...2 16 MEMO ...
Page 53: ...3 12 MEMO ...
Page 114: ...4 61 MEMO ...