8
1. Main features
1.1. Specifications
Power Supply
12 V DC (Vehicle battery).
Display
Back lit LCD, 4 lines x 20 characters, alphanumeric
Printer
Thermal, 24 columns.
Hardware
Electronic control board and microcontroller
Pump
Maximum flow = 5.5 litres/min;
Minimum flow = 4.5 litres/min;
Maximum pressure =9 bar
Dimensions
W = 650 mm, H = 1130 mm, D = 450 mm
Weight
~61 Kg
Operating temperature
+ 5 ° C
↔
+ 40°C
1.2. Machine parts
➊
Printer
➋
Control panel
➌
Connection hoses
➍
Used fluid tank compartment
➎
New fluid tank compartment
➏
Battery power cables
➐
Filter cartridges
1.3. Control panel
➊
Visual indicator of flow: The backlight of the visual indicator is activated when the ATF is in the process
of “LOOP”, which means the connection between transmission and radiator is closed and the pump
stopped. This allows you to check the status of the automatic transmission fluid.
➋
Selection button:
• Turn to select correct option or to increase / decrease selected value per 100ml steps
• Push short to select an option and to confirm (= OK button)
• Push long to return to the previous menu (= ESC/STOP)
➌
GREEN light: normally off; it flashes during cycle performance. - It remains on at end of cycle.
➌
RED light: Normally off. It starts flashing in case of alarms due to:
• insufficient new fluid;
• insufficient volume for receiving used fluid in the used fluid tank;
• absence of required additive in auxiliary tank;
• Failures or defects.