4-14
REMOVING THE OVERLOAD PROTECTOR
AND THE COMPRESSOR
1.
Unplug air conditioner or disconnect power.
2.
Remove the unit from the wall sleeve (see
pages 2-10 and 2-11 for the procedure).
3.
To remove the overload protector:
a) Remove the hex cap nut and the nylon
flat washer from the terminal cover and
remove the cover.
b) Disconnect the black wire from the com-
pressor terminal, and the black wire
from the overload protector terminal.
REASSEMBLY NOTE:
When you reinstall the
terminal cover on the compressor, make sure
that the overload protector is centered in the
gasket hole, and does not sit on any portion of
the gasket.
4.
To remove the compressor:
a) Remove the overload protector (see
step 3).
b) Disconnect the blue wire from the
S (V)
terminal and the red wire from the
R (U)
terminal of the compressor.
c) Remove the gasket.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Hex Cap Nut
& Nylon Flat
Washer
Terminal
Cover
Black
Wires
Overload
Protector
Compressor
Terminals
Blue
Wire
Red
Wire
Gasket