4-16
REMOVING THE EVAPORATOR
1.
Unplug air conditioner or disconnect power.
2.
Remove the unit from the wall sleeve (see
pages 2-10 and 2-11 for the procedure).
3.
Braze on an access valve and discharge
the sealed system refrigerant into an ap-
proved recovery system.
4.
Remove the screen, air deflector, and
deck from the front of the unit (see steps 3,
4, and 5 on page 4-9).
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Screen
5.
Remove the four hex-head screws from
the control chassis, and rotate the chassis
down.
Air Deflector
Deck
6.
Remove the two hex-head screws from
the evaporator mounting plate, located on
the right side of the chassis.
4 Control Chassis Screws
Evaporator
Mounting Plate
Screws
Summary of Contents for ATE0743RPP
Page 20: ...2 12 NOTES ...
Page 30: ...3 10 NOTES ...
Page 71: ...7 5 WIRING DIAGRAMS DIAGRAM 1 ...
Page 72: ...7 6 DIAGRAM 3 DIAGRAM 2 ...
Page 73: ...7 7 DIAGRAM 4 DIAGRAM 5 ...
Page 74: ...7 8 DIAGRAM 7 DIAGRAM 6 ...
Page 75: ...7 9 DIAGRAM 8 ...
Page 84: ...7 18 NOTES ...
Page 90: ...8 6 NOTES ...
Page 92: ...CORPORATION ...