Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can
result in death, fire, or electrical shock.
1.
Plug into a grounded 3 prong outlet.
2.
Reconnect power.
Direct Wired Models
Cord Connected Models
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Field wiring connections for direct-wired mod-
els can be done in one of 2 ways:
• Using field-supplied conduit and wires.
• Using the Conduit with Junction Box Kit
accessory.
FIELD WIRING CONNECTIONS
1.
Disconnect power.
2.
Remove the PTAC/PTHP front cover us-
ing the thumbscrews.
3.
Route the incoming power supply through
suitable conduit to the PTAC/PTHP con-
trol box.
4.
Remove the 4 screws holding the control
box.
5.
Pivot the control box down, pull the chas-
sis pigtail wires into the control box, and
remove the bushing from the hole. The
field-supplied wires will be routed through
this hole.
1. Remove these screws.
2. Do not remove these screws.
3. Bushing
1
2
3
1
2
1. Bushing
2. Control box
2
1
Summary of Contents for ATE0743RPP
Page 20: ...2 12 NOTES ...
Page 30: ...3 10 NOTES ...
Page 71: ...7 5 WIRING DIAGRAMS DIAGRAM 1 ...
Page 72: ...7 6 DIAGRAM 3 DIAGRAM 2 ...
Page 73: ...7 7 DIAGRAM 4 DIAGRAM 5 ...
Page 74: ...7 8 DIAGRAM 7 DIAGRAM 6 ...
Page 75: ...7 9 DIAGRAM 8 ...
Page 84: ...7 18 NOTES ...
Page 90: ...8 6 NOTES ...
Page 92: ...CORPORATION ...