TROUBLESHOOTING CHARTS
Refrigerant System—Cooling
Refrigerant System—Heating
Low Suction Pressure
High Suction Pressure
Low Head Pressure
High Head Pressure
Low Load Conditions
High Load Conditions
Low Load Conditions
High Load Conditions
Low Airflow Across
Evaporator
High Airflow Across
Evaporator
Refrigerant System
Restriction
Low Airflow Across
Condenser
Overcharged System
Refrigerant System
Restriction
Reversing Valve
Not Fully Seated
Reversing Valve
Not Fully Seated
Non-Condensables
(Air) In System
Undercharged System
Overcharged System
Undercharged System
Moisture In System
Defective Compressor
Defective Compressor
Low Suction Pressure
High Suction Pressure
Low Head Pressure
High Head Pressure
Low Airflow Across
Condenser
Outdoor Ambient
Temperature Too High
Outdoor Ambient
Temperature Too High
For Operation In Heating
Refrigerant System
Restriction
Refrigerant System
Restriction
Reversing Valve
Not Fully Seated
Reversing Valve
Not Fully Seated
Non-Condensables
(Air) In System
Undercharged System
Overcharged System
Overcharged System
Undercharged System
Moisture In System
Defective Compressor
Defective Compressor
Low Airflow Across
Evaporator
Summary of Contents for ATE0743RPP
Page 20: ...2 12 NOTES ...
Page 30: ...3 10 NOTES ...
Page 71: ...7 5 WIRING DIAGRAMS DIAGRAM 1 ...
Page 72: ...7 6 DIAGRAM 3 DIAGRAM 2 ...
Page 73: ...7 7 DIAGRAM 4 DIAGRAM 5 ...
Page 74: ...7 8 DIAGRAM 7 DIAGRAM 6 ...
Page 75: ...7 9 DIAGRAM 8 ...
Page 84: ...7 18 NOTES ...
Page 90: ...8 6 NOTES ...
Page 92: ...CORPORATION ...