4-2
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
REMOVING THE INDOOR THERMOSTAT,
MODE (SYSTEM) SWITCH, AND HEAT ANTICIPATOR
1.
Unplug air conditioner or disconnect power.
2.
Remove the front cover from the unit (see
page 2-11 for the procedure).
3.
Remove the four hex-head screws from
the control panel and lift the panel off the
unit.
Refer to the photos at the top of the right
column.
4.
Pull the control knobs off the control shafts.
5.
If you are replacing the indoor thermostat,
remove the two hex-head mounting
screws, as shown in the round inset.
Control Panel
Screw
Screw
Screw
Screw
4 Control Chassis Screws
7.
Rotate the top of the chassis down so that
you can access the components.
6.
Remove the four hex-head screws from
the control chassis.
Control Chassis
Indoor
Thermostat
Locking
Tab
Control
Chassis
Mode
Switch
Indoor Thermostat
Screws