4-8
REMOVING THE REMOTE CONTROL UNIT FAN SWITCH
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
4.
Lift the remote control panel off the unit,
and turn it over.
5.
Disconnect the wires from the fan switch
terminals.
6.
Press in on the locking arms and push the
switch out of the control panel cutout.
1.
Unplug air conditioner or disconnect power.
2.
Remove the front cover from the unit (see
page 2-11 for the procedure).
3.
Remove the four hex-head screws from
the remote control panel.
Remote
Control Panel
Screw
Screw
Screw
Screw
REASSEMBLY NOTE:
Make sure that you
position the fan switch with the pin 1 terminal
positioned as shown before you reinstall it in
the control panel cutout.
BK
BU
RD
Pin 1