4-15
f) Remove the three 1/2
″
hex bolts from
the compressor’s rubber shock mounts.
d) Braze on an access valve and dis-
charge the sealed system refrigerant
into an approved recovery system.
e) Disconnect the high side line from the
compressor, and the suction line from
the accumulator.
g) Lift the compressor from the unit and
remove the three rubber shock mounts.
1/2
″
Hex Bolt
High Side Line
To Compressor
Suction Line
To Accumulator
Rubber Shock
Mount (1 of 3)