7-11
(#5) COMPRESSOR COOLING (HEAT PUMP MODELS)
(#6) COMPRESSOR COOLING (NON-HEAT PUMP MODELS)
L1
L2
L1
2
3
2
BK
BK
BU
BK
BU
R
R
R
S
C
C
H
SYSTEM
SWITCH
COM
L2
SYSTEM SWITCH
COMPRESSOR
OVERLOAD
3
5
SYSTEM
SWITCH
SYSTEM
SWITCH
6
4
FUSE
(265V
MODELS
ONLY)
MAIN
THERMOSTAT
L2
L1
2
3
2
BK
BU
BU
R
BK
BU
R
R
R
S
C
C
H
SYSTEM
SWITCH
DEFROST
THERM.
COM
L2
SYSTEM SWITCH
COMPRESSOR
OVERLOAD
3
5
SYSTEM
SWITCH
HOT START
RELAY
2
3
4
5
L1
FUSE
(265V
MODELS
ONLY)
MAIN
THERMOSTAT
(#4) HEAT—FAN MOTOR CYCLING
L1
L2
L1
2
1
2
BK
BK
R
BU
Y
R
BR
Y
R
C
F
SYSTEM
SWITCH
SYSTEM
SWITCH
COM
L2
SYSTEM SWITCH
FAN MOTOR
1
5
SYSTEM
SWITCH
FAN CYCLE
SWITCH
9
L
H
1
2
FUSE
(265V
MODELS
ONLY)
(HIGH)
(LOW)
(9 - H = HIGH)
(9 - L = LOW)
MAIN
THERMOSTAT