4-10
REMOVING THE FAN MOTOR
1.
Unplug air conditioner or disconnect power.
2.
Remove the unit from the wall sleeve (see
pages 2-10 and 2-11 for the procedure).
3.
Remove the heater and limit switch from
the unit (see page 4-9 for the procedure).
4.
Lower the control chassis so you can
access the fan motor wires (perform steps
3, 6, and 7 on page 4-2).
5.
Disconnect the black and red fan motor
wires from mode switch terminals H and L.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
YL Fan Mtr
(Black Ring)
BR Fan Mtr
(Green Ring)
Mode
Switch
6
5
COM
L1
H
L
L2
2
9
1
3
8
4
7
BK
(Fan Mtr)
RD
(Fan Mtr)
6.
Disconnect the brown and yellow fan mo-
tor wires from the capacitor terminals.
7.
Pull the ends of the four fan motor wires
through the chassis hole and remove them
from the plastic wire clamp.
Wire Clamp
Chassis Hole