4-13
REMOVING THE CONDENSATE VALVE BELLOWS
1.
Unplug air conditioner or disconnect power.
2.
Remove the unit from the wall sleeve (see
pages 2-10 and 2-11 for the procedure).
3.
Remove the two hex-head screws from
each of the condenser fan shroud mount-
ing brackets and remove the brackets.
4.
Remove the remaining three hex-head
screws from the condenser shroud (1 bot-
tom and 2 side screws).
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Condenser
Fan Shroud
Side Screw (1 of 2)
Bottom Screw
Shroud Brackets &
Screws (2 each)
5.
Tilt the top of the condenser fan shroud
forward and pull the left end away from the
condenser just far enough to access the
condensate valve bellows.
Condenser Fan Shroud
6.
Remove the left 5/16
″
nylon mounting nut
on the condensate valve bellows, and
loosen the right nut approximately half
way on the chassis pan stud.
Remove Nut
Loosen Nut
Condensate Valve Bellows
(Front View)
Left Side View