7-16
(#15) ELECTRIC HEAT—HOT START SENSOR CLOSED—
ROOM BELOW 50
°
F, REVERSING VALVE ENERGIZED (SEE #14)
(HEAT PUMP MODELS)
ELECTRIC
HEATER
HEATER
LIMIT SW
L1
BU
BK
TN
BK
RD
1
FUSE (265V
MODELS ONLY)
3
R
HEATING
RELAY
TRANSFORMER
COM
24V
W
WALL THERMO.
L2
BU
BR
3
1
4
6
HOT START
RELAY
HOT START
SENSOR
ELECTRIC
HEATER
HEATER
LIMIT SW
L1
BK
TN
DEFROST
THERM.
4
6
RD
BR BU
BU
RD
1
5
4 1
3
1
2
R
HEATING
RELAY
HEATING
RELAY
HOT START
RELAY
TRANSFORMER
COM
24V
W
WALL THERMO.
L2
FUSE (265V
MODELS ONLY)
(#16) ELECTRIC HEAT—HOT START SENSOR OPEN—ROOM ABOVE 65
°
F,
AND OUTDOOR AMBIENT BELOW 47
°
F, REVERSING VALVE ENERGIZED
(SEE #14) (HEAT PUMP MODELS)