![VNS UD100 User Manual Download Page 41](http://html1.mh-extra.com/html/vns/ud100/ud100_user-manual_1043367041.webp)
UD100 User Guide Document: UD100-3
----------------------------------------------------------------------------------------------------------------------------- -----------
40
➢
Check input/output LED indicators and make sure to have correct system connection.
➢
User can set [Frame Sync] at [Disable] to eliminate [Source-Search] in projector during setup. After
finish the setup, please set to [Normal] to get synchronization in all outputs.
5. Geometry alignment
5.1. Select Appropriate Grid Pattern for geometry alignment
Grid pattern is required for geometry alignment. The area of grid pattern is the display area of the
source image. User can activate test pattern through [Pattern] hotkey in remote controller or through
WebGui and PC tool.
➢
The OSD show-up time can be determined by [Options]
→
[Accessibility]
→
[Menu Time Out]. If set
at “0”, the OSD will show up all the time unless input timing is changed or OSD [Exit].
➢
If user finds different grid size in different projectors, please check the grid pattern size, output
timing setting and the aspect ratio settings in each projector. GeoBox needs to set at [Full Screen]
display mode under [Image Properties]
→
[Scaling] menu.
➢
If user executes Geometry alignment, the pattern will appear automatically after select the
adjusting point and press Enter.
➢
There are 6 pattern styles for user to select. When user presses [Pattern] key, it will circulate from
[White]
→
[Red]
→
[Green]
→
[Yellow]
→
[Cyan]
→
[White grid + background]
→
[OSD menu +
Background]
➢
If user wants to apply his own test pattern, please select the last transparent pattern mode to show
up user pattern.
➢
User can select different pattern color for each projector while doing edge blending setup.
➢
Note: some projector RGB pixels are not at the same location. It will cause position deviation.
Please recheck with White grid pattern for final result.
➢
User can see geometry adjusting value when select [Back OSD] display style.
PS. User can select the last pattern profile [OSD Value + background] and apply external test pattern for
geometry alignment.