VD120 Series Inverter User Manual Parameter Description
-
101
-
Set
value
Function
Description
0
Running frequency
0~maximum output frequency
1
Set frequency
0~maximum output frequency
2
Output current
0~2 times of rated motor current
3
Output torque
0~2 times of rated motor voltage
4
Output power
0~2 times of rated power
5
Output voltage
0~1.2 times of inverter rated power
6
PULSE input
0.01kHz~100.00kHz (100% corresponding 100.0kHz)
7
AI1
0V~10V
8
Reserved
Reserved
9
Reserved
Reserved
10
Length
0~maximum set length
11
Count value
0~Max count value
12
Communication setting
0.0%~100.0%
13
Motor rotate speed
0~maximum output frequency corresponding rotate speed
14
Output current
100% corresponding 1000.0A
15
Output voltage
0.0V~1000.0V (100% corresponding 100.0kHz)
F6-15
HDO1 Output Max
Frequency
0.01kHz~100.00kHz
50.00kHz
○
When selecting HDO1 terminals as pulse output, the function code is used to select the maximum
frequency value of the output pulse.
F6-16
AO1 Output Voltage
Lower Limit
0.00V~10.00V
0.00V
○
F6-17
Corresponding Setting
Value of AO1 Output
Voltage Lower Limit
0.0%~F6-19
0.0%
○
F6-18
AO1 Output Voltage
Upper Limit
0.00V~10.00V
10.00V
○
F6-19
Corresponding Setting
Value of AO1 Output
Voltage Upper Limit
F6-17~100.0%
100.0%
○
F6-20
AO1 Output Filter Time 0.00s~10.00s
0.00s
○
The function code used to set the relation of analog output voltage and its representing set value.
When AO1 output is the current output, 1mA current is equal to 0.5V voltage, so 20mA current equal
to10V (AO1 jumper wire to the current file).