Function Parameter Table VD120 Series Inverter User Manual
-
44
-
Fb-34
Accumulative
Power-on
Reached Time
Setting
0h~65000h
0h
○
Fb-35
Accumulative
Running
Reached Time
Setting
0h~65000h
0h
○
Fb-36
Timing
Function
Selection
0: Disabled
1: Enabled
0
○
Fb-37
Timed Running
Time Selection
0: Fb-38 setting
1: AI1
Analog input range corresponding to
the Fb-38
0
○
Fb-38
Timed Running
Function
0.0Min~65000.0Min
0.0Min
○
Fb-39
Module
Temperature
Reached
0°C~100°C
75°C
○
Fb-40
Lower Limit of
AI1 Input
Voltage
Protection
Value
0.00V~Fb-41
3.10V
○
Fb-41
Upper Limit of
AI1 Input
Voltage
Protection
Value
Fb-40~10.00V
6.80V
○
Fb-42
Wakeup
Frequency
Dormancy frequency (Fb-44)~max
frequency (F0-10)
0.00Hz
○
Fb-43
Wakeup Delay
Time
0.0s~6500.0s
0.0s
○
Fb-44
Dormancy
Frequency
0.00Hz~wakeup frequency (Fb-42)
0.00Hz
○
Fb-45
Dormancy
Delay Time
0.0s~6500.0s
0.0s
○
Fb-48
Timing Braking
Frequency
0.00Hz~50.00Hz
1.50Hz
○
Fb-49
Timing Braking
Time
0.0s~60.0s
2.0s
○
Fb-50
Terminal Jog
Priority
0: Disabled
1: Enabled
1
○
Fb-51
Swing
Frequency
0: Relative to center frequency
0
○