Function Parameter Table VD120 Series Inverter User Manual
-
22
-
F3-20
Max Weak
Magnetic
Current
1%~300%
50%
◎
F3-21
Weak Magnetic
Automatic Gain
Adjustment
10%~500%
100%
○
F3-22
Weak Magnetic
Integral
Multiples
2~10
2
○
F3-23
Torque Boost
Coefficient
0.0%~60.0%
10.0%
○
F3-24
Torque Boost
Cutoff
Frequency
0.00Hz~max frequency
20.00Hz
◎
F3-25
Exciting
Current
Compensation
Gain
0~500
0
○
F3-26
Torque Current
Compensation
Gain
0~500
0
○
F3-27
Torque
Response Gain
1~1000
10
○
F4 Motor V/F Control Parameter
Function
Code
Parameter
Name
Setting Range
Factory
Default Value
Property
F4-00
V/F Curve
Setting
0: Straight line V/F
1: Multipoint V/F
2: Square V/F
3: 1.2#power V/F
4: 1.4#power V/F
5: 1.6#power V/F
6: 1.8#power V/F
7: V/F complete separation mode
8: V/F half separation mode
0
◎
F4-01
Torque Boost
Mode Selection
0: Automatic torque boost
1: Manual torque boost
0
◎
F4-02
Manual Torque
Boost
0.0%~30.0%
Model
dependent
○
F4-03
Manual Torque
Boost Cutoff
Frequency
0.00Hz~max frequency
50.00Hz
◎