Parameter Description VD120 Series Inverter User Manual
-
96
-
Setup frequency
or torque
Setup frequency
or torque
100%
100%
AI
AI
0V/0mA
0V/0mA
-100%
10V/20mA
10V/20mA
Fig.6-15 Corresponding Relationship between Analog Reference and Setting
F5-27
AI Curve 2 Min Input
-10.00V~F5-29
0.00V
○
F5-28
Corresponding Setting
of AI Curve 2 Min Input
-100.0%~+100.0%
0.0%
○
F5-29
AI Curve 2 Max Input
F5-27~+10.00V
10.00V
○
F5-30
Corresponding Setting
of AI Curve 2 Max Input
-100.0%~+100.0%
100.0%
○
F5-31
AI 2 Filter Time
0.00s~10.00s
0.10s
○
The function and using method of curve 2, please refer to the insctructions of curve 1.
F5-32
AI Curve 3 Min Input
-10.00V~F5-34
0.00V
○
F5-33
Corresponding Setting
of AI Curve 3 Min Input
-100.0%~+100.0%
0.0%
○
F5-34
AI Curve 3 Max Input
F5-32~+10.00V
10.00V
○
F5-35
Corresponding Setting
of AI Curve 3 Max Input
-100.0%~+100.0%
100.0%
○
F5-36
AI3 Filter Time
0.00s~10.00s
0.10s
○
The function and using method of curve 3, please refer to the instructions of curve 1.
F5-37
Pulse Min Input
0.00kHz~F5-39
0.00kHz
○
F5-38
Corresponding Setting
of Pulse Min Input
-100.0%~+100.0%
0.0%
○
F5-39
Pulse Max Input
F5-37~100.00kHz
50.00k
Hz
○
F5-40
Corresponding Setting
-100.0%~+100.0%
100.0%
○