Parameter Description VD120 Series Inverter User Manual
-
136
-
A0-01
Torque Setting Source
Selection under the
Torque Control Mode
0: Digital setting (A0-02)
1: AI1
2: Reserved
3: Reserved
4: PULSE
5: Communication setting
6: Reserved
7: Reserved
8: Keypad Potentiometer (the full scale
of option 1~7 corresponding digital
setting of A0-02)
0
◎
A0-02
Torque Digital Setting
under the Torque Control
Mode
-200.0%~2000%
100.0%
○
A0-01 is used to select the torque setting source, a total of 8 kinds of torque setting method.
Torque setting use the relative value, and 100% corresponding the rated torque of the inverter. Set
range -200.0%~200.0%, which shows that frequency inverter maximum torque of the 2 times the
rated torque of the inverter.
When the torque is setting using 1~7, communication, analog input, and 100% of pulse input
corresponding A0-02.
A0-03
Max Frequency Source
Selection under the
Torque Control Forward
0: Digital setting (A0-04)
1: AI1
2: Reserved
3: Reserved
4: PULSE
5: Communication setting
6: Keypad potentiometer
0
◎
A0-04
Max Frequency Digital
Setting under the Torque
Control Forward
0.00Hz~max frequency
50.00Hz
○
A0-05
Max Frequency Source
Selection under the
Torque Control Reverse
0: Digital setting (A0-06)
1: AI1
2: Reserved
3: Reserved
4: PULSE
5: Communication setting
6: Keypad potentiometer
0
◎
A0-06
Max Frequency Digital
Setting under the Torque
Control Reverse
0.00Hz~max frequency
50.00Hz
○
Used to set the forward or reverse maximum running frequency of the inverter under the torque
control mode.
When the inverter torque control, if the load torque is less than the motor output torque, the motor
speed will continue to rise, to prevent mechanical systems appear coasters and other accidents, must
limit the motor highest speed when torque control.