VD120 Series Inverter User Manual Function Parameter Table
-
37
-
Upon the First
Time Fault
F9-29
Power on Time
Upon the First
Time Fault
-
-
●
F9-30
Running Time
Upon the First
Time Fault
-
-
●
F9-33
Fault
Automatic
Reset Times
0~20
0
○
F9-34
Fault
Automatic
Reset Interval
Time
0.1s~100.0s
1.0s
○
F9-35
Fault DO
Action
Selection
During the
Fault
Automatic
Reset
0: No action
1: Action
0
○
F9-36
Fault
Protection
Action
Selection 1
Unit’s digit: motor overload (11)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Ten’s digit: input phase loss (13)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Hundred’s digit: output phase loss
(14)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Thousand’s digit: external fault (17)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Ten thousand’s digit: communication
abnormal (18)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
0x00000
○
F9-37
Fault
Unit’s digit: reserved
0x00000
○