Function Parameter Table VD120 Series Inverter User Manual
-
50
-
Fd-01
Data Format
0: No verify (8-N-2)
1: Even verify (8-E-1)
2: Odd verify (8-O-1)
3: 8-N-1
0
○
Fd-02
Local Address
0: is broadcast address
1~247: slave address
1
○
Fd-03
Response
Delay
0ms~20ms
2ms
○
Fd-04
Communicatio
n Timeout Time
0.0 (disabled)
0.1s~60.0s
0.0s
○
Fd-05
Data Transfer
Format
Selection
0: Non standard MODBUS protocol
1: Standard MODBUS protocol
1
○
Fd-06
Communicatio
n Read Current
Resolution
0: 0.01A
1: 0.1A
0
○
FF User Parameters Group
Function
Code
Parameter
Name
Setting Range
Factory
Default Value
Property
FF-00
User Password
0:~65535
0
○
FF-01
Parameter
Initialization
0: No operation
1: Restore factory default setup
value, exclude of motor parameter
2: Clear the record information
3: Backup user current parameters
4: Restore user current parameters
0
◎
FF-03
Function Code
Display
Selection
Unit’s digit:
0: Not display A group
1: Display A group
Ten’s digit:
0: Not display b group
1: Display b group
0x11
○
FF-04
Function Code
Modify
Property
0: Can modify
1: Can’t modify
0
○
FF-05
Fast
Debugging
Setting
Unit’s digit: user custom parameter
group display selection
0: Not display
1: Display
Ten’s digit: user change parameter
group display selection
0: Not display
0x10
○