Call Control
18
SBX IP 320 Features & Operation Guide
STATION COS
CO COS
CO TO CO LINE COS
PBX Dialing Codes-There are 5 PBX access codes (2 digits) to enter the system and access a
CO line via PBX. A CO line marked as a PBX line will not be governed by any station or CO
line COS until a recognized PBX code is dialed.
COS 1
There is no restriction to dial.
COS 2
Monitored by Exception Table A
COS 3
Monitored by Exception Table B
COS 4
Monitored by Exception Table A & B
COS 5
Long distance call is not allowed; longer than 8 digits
COS 6
Long distance call is not allowed; max. 8 digits may be dialed
COS 7
Only intercom, paging and emergency calls are allowed; no dialing allowed on CO
lines
COS 8
Monitored by Exception Table C
COS 9
Monitored by Exception Table C
COS 1
There is no restriction. Monitored by STA COS.
COS 2
Monitored by Exception Table A & STA COS 2/4.
COS 3
Monitored by Exception Table B & STA COS 2/4
COS 4
Long distance call is not allowed for all STA COS; max. 8 digits may be dialed
COS 5
Overrides STA COS 2, 3, 4, 5, 6, no COS restriction
COS 1
There is no restriction to dial
COS 2
Monitored by Exception Table A
COS 3
Monitored by Exception Table B
COS 4
Monitored by Exception Table A & B
COS 5
Long distance call is not allowed; longer than 8 digits
COS 6
Long distance call is not allowed; only max. 8 digits may be dialed
COS 7
Only intercom, paging and emergency call are allowed; no dialing allowed on CO lines
COS 8
The assignments in the Exception Table C are monitored for allow and deny numbers
COS 9
The assignments in the Exception Table D are monitored for allow and deny numbers