Station Message Detail Recording (SMDR)
193
SBX IP 320 Features & Operation Guide
•
If user dials any number with a programmed long distance code as the first and second
digit dialed or any number with more than maximum local call digit count, it will be
regarded as a long distance call. (Max. local call digit count is programmable and the
default value is 7.)
•
The SMDR output records contain the following:
•
5-digit station call originator (terminating for incoming) filed
•
3-digit used CO line field
•
8-digit call duration field (HH:MM:SS)
•
8-digit year, month, and day (YY/MM/DD)
•
5-digit time of day call originator field
•
1-digit call identification digit-first digit in digit dial field
•
18-digit collected dial digit field
•
2-digit account group number field
•
5-digit pulse metering count field
•
10-digit call cost field
•
12-digit account code field
•
When the SMDR storage pools are almost exhausted, the system gives "Buffer full"
warning signal to the attendant. The Attendant station LCD will indicate how many
SMDR records remain to store at some intervals.
•
Some stations can be grouped to count the billing with a SMDR receipt using an SMDR
account group.
•
The "SLT DTMF RLS TMR" should be adjusted to a reasonable value in order to print all
digits that SLT dialed.
•
ICM SMDR is not supported for Lost Calls.
•
Only Calling Party NO is displayed at STA field.
•
Only the Station No which is getting an ICM call is displayed at DIALED field. (ex) - E
xxx : E is internal call, S is SM).
•
SMS SMDR is also controlled by PGM 177 - FLEX 17, 18 option ON/OFF.
•
ICM SMDR record format is same as existing SMDR record format.
•
ICM HUNT Call SMDR record is same as just ICM Call. For example, Station 100 call
to Hunt 620, and answer 620 member Station 110, then [STA] field Station 100, and
[DIALED] field Station 110.