Paging
156
SBX IP 320 Features & Operation Guide
Private Line
CO Lines in the system can be assigned for exclusive use by one or more DKTU users. Private
lines are assigned to CO Line Group 00 and an appearance (Flexible CO button) is required at
the DKTU (Loop or Pool keys cannot be used).
Operation
A private line will operate as a normal CO Line, except access is limited to assigned stations.
Condition
•
A Private line cannot be picked up.
Admin Programming
•
CO Line Group (PGM 141 - FLEX 1)
Paging
Internal, External, All-Call, and Meet-Me Page
Stations can individually be allowed or denied the ability to make pages. This applies to all
internal zone paging and all external zone paging. A station denied access to paging may still
answer a Meet-Me Page announcement.
There is one External Paging Zone available. External paging requires an externally-provided
amplifier and paging system. External page can have a relay contact associated to it.
There are ten internal paging zones available. A station can be in any or all zones or in no zone
at all. Stations not assigned to a page group can still make page announcements, if allowed in
station programming. Stations can be assigned to a page group in order to receive pages but not
allowed to make page announcements.
Stations to receive pages for a given zone are assigned to the zone. A page warning tone, if
assigned, will be provided to the page zone(s) prior to the audio connection. The user is allowed
to continue the page for a specified period. After the time expires, the user is disconnected and
the page zone(s) returns to idle.