Outgoing Call Access
145
SBX IP 320 Features & Operation Guide
Ex. 3 Make another CO Access Code - The SBX IP 320 system has VOIP CO Lines and normal
CO Lines; system administrator wants to access VOIP CO using code 7, and access normal CO
Lines using code 9 (as the default CO Access Code).
Ex. 4 Password for specific dial number - The international access code is 001; system
administrator allows international calls by only those users who know the system password.
Conditions
•
There are 6 LCR modes. The mode is determined by PGM 220 - FLEX 1.
- LCR Access Mode 00 (M00): LCR call is disabled.
•
The leading digits can be duplicated. FLEX 2 and the DMT index make each entry
unique.
PGM 106
Remove/change numbering plan which starts with "7".
PGM 141
PGM 117
PGM 161-3
Set normal CO Lines to CO
group 1
Set VOIP CO Lines to CO
group 2
Enable access CO group 01,
02
Override 1st CO Group: OFF
PGM 220
PGM 221 (LDT)
PGM 222 (DMT)
LCR MODE
M02, M12, M13
(Internal LCR enabled)
Bin 000
LCR TYPE: INT
LCR CODE: 7
DMT: 00 00 00
Bin 00
Remove Position: 01
Remove Number: 01
CO Group: 02
PGM 220
PGM 221 (LDT)
PGM 222 (DMT)
LCR MODE
M12, M13
(LOOP/CO LCR enabled)
Bin 000
LCR TYPE: COL
LCR CODE: 001
DMT: 00 00 00
Check Password: ON
Bin 00
CO Group: 01