Call Handling
51
SBX IP 320 Features & Operation Guide
In-Room Indication
A supervisor presses In-Room Indication button and [HOLD/SAVE] button at the idle state.
Then each LED of In-Room Indication buttons of all members are turned ON.
10 groups can be programmed. Each group has at most 20 members excluding the Supervisor.
To program a flexible button as the "In-Room Indication button":
1.
Press the [TRANS/PGM] button and the flexible button to be assigned.
2.
Dial the code ([TRANS/PGM] + *8)
3.
Press the [HOLD/SAVE] button.
Operation
To Activate or Deactivate the In-Room Indication button:
1.
Check if Supervisor station is the idle state and In-Room Indication button is
programmed.
2.
Press the In-Room Indication button and press the [HOLD/SAVE] button.
Conditions
•
If the Supervisor station is not Idle, the In-Room Indication button does not work.
•
If a station presses the In-Room Indication button but the station is not a supervisor, an
error tone is heard.
•
If the [HOLD/SAVE] button is not pressed within 5 seconds after the In-Room Indication
button is pressed, the station goes back to an Idle state.
Admin Programming
•
In-Room Indication Supervisor (PGM 183 - FLEX 1)
•
In-Room Indication Member (PGM 183 - FLEX 2)