2.2
Mounting Hole Locations
The GASGUARD Distribution System racks are mounted to the facility floor
using four (4) anchors, one in each corner of the base.
Highest tension load when resisting tip over is approximately 580 pounds (2580 N)
per anchor, as calculated utilizing seismic accelerations specified by SEMI S2-
93A. The facility floor mounting location should be clean and must be level.
The GASGUARD Distribution System Wall Mounts are mounted to vertical walls
or supporting structure using four (4) 11/32” (8.7 mm) diameter holes, two (2 ea.)
in the horizontal Unistrut
®
channels mounted to the back of the VMB system
assemblies or six (6) 13/32” (10.3 mm) diameter holes, three (3 ea.) in the vertical
Unistrut
®
channels mounted on the back of the VMP system assemblies.
For 24” VMB or VMP rack anchoring see Section 2.2.1. For 30” VMB or VMP
rack anchoring see Section 2.2.2.