VANGUARD 1X

120V

25799 Jefferson Ave.

  

  

Murrieta, CA 92562

  

  

1-800-VANIMAN (826-4626)

  

  

www.vaniman.com

  

 

 

[email protected]

10310-I-09/21 PAGE 1

PACKING LIST

 

 

1 - Vanguard 1X unit

 

1 - Power Cord 

 

1 - Hose Assembly

ASSEMBLY INSTRUCTIONS

1. Remove the unit and other parts from the box. Check against the packing list.
2. Plug the removable power cord into the socket labeled “POWER” on the top of the unit. Plug the other 

end into a standard wall socket. Try the unit by turning the switch to the “ON” position. 

3. The vacuum hose supplied slips onto the vacuum connection on top of the unit and the other end con

-

nects to the collection device desired. The ideal location for the unit is under the bench where the user 

works. The hose may be shortened by removing the hose cuff from one end and carefully cutting with 

a sharp knife. The hose cuff threads onto the hose with a left-hand thread. Longer hoses and adapters 

are available from your dealer. We recommend that you try to keep the total length of hose less than 6 

feet between the unit and the dust collection point; longer hose will reduce suction. 

MAINTENANCE

1. Filter Bag Replacement

 - When a noticeable drop in suction occurs with the unit or it shuts down or 

the filter bag is two thirds full, replace the filter bag. 

DO NOT 

attempt to clean out the filter bag. Replace 

with a new Vaniman filter bag.  Change the filter bag by unscrewing the two thumb screws on the front 

of the unit and pull out the front cover plate to expose the filter bag compartment. Remove the used 

filter bag by sliding it off the inlet tube; the front of the cardboard reinforcement may need to be tilted 

downward slightly to remove the bag easily. Check the inside of the filter bag compartment. If dust is 

present please clean the compartment. Cause for residual dust may be due to improper installation. 

Vacuuming the excess dust will increase the life of the unit. Changing the filter bag regularly will save 

wear-and-tear on the motor. Re-order 

P/N VMC-A400-5

 

2. 

Installing a new filter bag

- Slip the cardboard reinforcement, with rubber seal, over the inlet tube. 

You may need to tilt the front of the cardboard downward and slip the back edge up past the tube end, 

then rotate upward over the tube end. Carefully tuck the edges of the filter bag into the filter bag com

-

partment. Replace the cover plate and gently tighten the thumb screws. Only gentle pressure need be 

used to make the gasket seal; the vacuum pressure will draw the cover tight. 

3. Circuit Breaker

 - The unit is protected by a circuit breaker on the right side of the unit.  In the unlikely 

event  there is an overload condition the breaker may trip.  If this happens reset the breaker by pushing 

on the white button until it clicks into place.

4. Motor Protection -

 If the motor becomes too hot it will automatically shutoff to prevent damage. To 

reset the thermal gauge, turn off or unplug the unit and allow the motor to cool down. Once it has cooled 

you may turn it back on and continue use.

5. Motor Brushes

 - This long life motor does not have replaceable brushes. Replacement motors can 

be ordered as 

P/N 97047

.

IMPORTANT SERVICE INFORMATION: