Any USB compatible device may be connected to either of the USB ports. For
instance, a memory device may be used to transfer Firmware from the device to the
Controller. Likewise, information can also be transferred from the Controller to
the memory device. As another example, a USB compatible mouse can be used to
navigate the Controller screens rather than using the touch screen capabilities.
Mouse Usage
The AP10 Controller is setup for mouse usage. All actions performed using the
touch screen can also be achieved using a mouse. This may become necessary in
the event of a touch screen failure. For the mouse icon to appear, move the mouse
at a 45 degree angle to the upper left-hand corner and right click. This will enable
the cursor.
Notes On Highlighting Text
In the Controller Configuration menu, it is possible modify setpoint, password, and
other numerical data. Rather than hitting the BACKSPACE key to eliminate the
exiting data, it is possible to highlight the data by simply dragging your finger
across the field and then entering the new data using the on-screen keypad.
Flow Valve (Z-Purge)
The flow valve is located on the right rear of the controller and can be adjusted via
the penetration into the gas cabinet between the pneumatic control bulkheads.